Back Back

Specifications

T6000


TEST RANGES

 
  Open-circuit Voltage (peak ) Short-circuit Current (peak)
LOGIC 10V 5mA
LOW 10V 150mA
MEDIUM 20V 1mA
HIGH 50V 1mA
LOCKOUT Restricts ranges that may be selected

RANGE SWITCHING

 
MANUAL Selects a single drive range.
AUTO Automatically selects a suitable range
CYCLE Switches through all ranges allowed at rate set by STEP RATE

TEST FREQUENCIES

 
LOW 90Hz
MED 500Hz
HIGH 2kHz

CHANNELS

 
Stand-Alone 64 ways each channel
PC-controlled 128 ways (single channel)

DISPLAY MODES

 
Stand-Alone A only, B only, A & B simultaneously
PC display 8 signatures simultaneously, zoom

PULSE GENERATOR

 
MODES DC, Pulse mode 1, Pulse mode 2
LEVEL 0 to +/-5V
WIDTH Sets pulse width (in Pulse modes)

TEST FUNCTIONS

 
Shorts Identifies short circuits between adjacent pins
Test Automatic comparison of A and B signatures. Test results shown in LCD display (stand alone) or on PC screen.
Tolerance Sets sensitivity for comparison
Loop Continuously executes Test or Shorts.

PC Requirements

 
DOS v3.3 (or higher), VGA colour monitor, RS232 port, 80286 recommended.

Power requirements

 
200-250V or 100-130V at 50/60Hz, 35VA.

Back Back