Specifications
|
T6000
|
|
TEST RANGES
|
|
| |
Open-circuit Voltage
(peak ) |
Short-circuit Current
(peak) |
| LOGIC |
10V |
5mA |
| LOW |
10V |
150mA |
| MEDIUM |
20V |
1mA |
| HIGH |
50V |
1mA |
| LOCKOUT |
Restricts
ranges that may be selected |
|
RANGE SWITCHING
|
|
| MANUAL |
Selects a
single drive range. |
| AUTO |
Automatically
selects a suitable range |
| CYCLE |
Switches
through all ranges allowed at rate set by STEP RATE |
|
TEST FREQUENCIES
|
|
| LOW |
90Hz |
| MED |
500Hz |
| HIGH |
2kHz |
|
CHANNELS
|
|
| Stand-Alone |
64 ways each
channel |
| PC-controlled |
128 ways
(single channel) |
|
DISPLAY MODES
|
|
| Stand-Alone |
A only, B
only, A & B simultaneously |
| PC display |
8 signatures
simultaneously, zoom |
|
PULSE GENERATOR
|
|
| MODES |
DC, Pulse
mode 1, Pulse mode 2 |
| LEVEL |
0 to +/-5V |
| WIDTH |
Sets pulse
width (in Pulse modes) |
|
TEST FUNCTIONS
|
|
| Shorts |
Identifies
short circuits between adjacent pins |
| Test |
Automatic
comparison of A and B signatures. Test results shown in
LCD display (stand alone) or on PC screen. |
| Tolerance |
Sets
sensitivity for comparison |
| Loop |
Continuously
executes Test or Shorts. |
|
PC Requirements
|
|
| DOS v3.3 (or
higher), VGA colour monitor, RS232 port, 80286
recommended. |
|
Power requirements
|
|
| 200-250V or
100-130V at 50/60Hz, 35VA. |
|